IEC 60870-5-104 I-frame buffer over-read vulnerability
CVE-2026-63033Medium
A specially crafted IEC 60870-5-104 I-frame message with an object count larger than the ASDU body can accommodate causes the InformationObject_ParseObjectAddress function to read one byte beyond the allocated message buffer. An attacker who can send network traffic to a device using this protocol could trigger this out-of-bounds read to access adjacent memory, potentially disclosing sensitive information.
Plain English summary of the NVD and CISA text, checked by machine against both.
Scores and dates
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Detail
Reports naming this CVE1 in total
· All CISA Advisories
MZ Automation lib60870 (opens in a new tab)